TI Ref. No:- 449374790

Invitation for Pre- Qualification on Request for Proposal on Embedded Power Generation Across Bedc Electricity PLC Franchise States, Nigeria

Organisation Details

Organisation Name BEDC ELECTRICITY PLC
Address 5, Akpakpava Road,
Benin City,
Edo State,  Tel : +234-08039012323
Email : rfp.embeddedgeneration@bedcpower.com
Country : Nigeria

Tender Details

Document Type Prequalification
Bidding Type Not Specified
Project Location Nigeria
Description Invitation for Pre- Qualification on Request for Proposal on Embedded Power Generation Across Bedc Electricity PLC Franchise States, Nigeria

Interested parties will be required to build, operate and evacuation power lines (11kV or 33kV) from their facilities to BEDCs designated off-take point

Prequalification Requirements:
Technical
Prospective Parties Shall Be Able To Demonstrate Capability To Build And Operate Modern Embedded Generation Facility With Minimum Generation Capacity Of 5mw. It Would Be An Added Advantage If Prospective Bidders Can Provide Evidence Of Similar Facilities Currently In Operation In Nigeria Or A Similar Environment.

Financial:
Minimum Average Turnover Requirement Per Sub Areas Shall Not Be Less Than N1.2 Billion Per Annum.
In Lieu Of The Ownership Of At Least A 5mw Facility Within The Franchise Area, The Applicant Shall Demonstrate That It Has Access To, Or Has Available Liquid Assets, Unencumbered Real Assets, Lines Of Credit, And Other Financial Means Sufficient To Meet The Construction And Operations Cash Flow Requirements For A Minimum Of 5mw Embedded Generation Facility.

The preliminary requirements for submitting the proposal are as follows
(1) The minimum capacity of power generation shall not be less than 5 MW
(2) The minimum power availability from the plant shall be above 90%
(3) The point of take-off shall be at 33kV or at 11kV voltage level. The sub-station up to grid shall be required to be maintained by the respective party i e. up to the 33kV or 11kV feeder breaker (from Power Plant to Linking Point of BEDC Network). The subsequent 33kV or 11kV line will be maintained by BEDC
4) The power generated shall have to be reserved exclusively for BEDC with a
redundancy factor of minimum 10% as spinning reserve
(5) The metering shall have to be done at the point of take-off ie. at 33kV or 11kV feeder whichever is the case and regular testing of metering equipment will be done as per mutual understanding once in a year between both parties.
(6) Power Plant shall be equipped with Modem Technology so that at least Data Acquisition is possible from Remote Location & instantaneous values can be fetched from site.
Deadline 08 Jan 2020

Related Documents

Disclaimer

The above text is Machine Translated. For accuracy, please refer to the text in the original language in the attached document. For any assistance, please feel free to contact customercare@tendersinfo.com